Clarisha, Mona (2021) PENGARUH AIR LINDI TERHADAP KUALITAS AIR SUMUR DI SEKITAR PEMUKIMAN TEMPAT PEMBUANGAN AKHIR (TPA) TALANG GULO KOTA JAMBI TAHUN 2021. S1 thesis, Fakultas Kedokteran dan Ilmu Kesehatan.
![]() |
Text
SKRIPSI MONA CLARISHA.pdf Restricted to Repository staff only Download (6MB) |
![]() |
Text
HALAMAN JUDUL.pdf Download (217kB) |
![]() |
Text
PERSETUJUAN DAN PENGESAHAN.pdf Download (432kB) |
![]() |
Text
ABSTRAK.pdf Download (188kB) |
![]() |
Text
BAB I.pdf Download (326kB) |
![]() |
Text
BAB V.pdf Download (188kB) |
![]() |
Text
DAFTAR PUSTAKA.pdf Download (314kB) |
Abstract
Background : The Talang Gulo Final Disposal Site (TPA) located on the South Ring Road, Kenali Asam Bawah Village, Kota Baru District, is the final waste disposal center that accommodates all waste in the city and its surroundings. TPA Talang Gulo operates with an open dumping/controlled landfill system so that groundwater will be polluted by leachate that is absorbed into the ground and has the potential to contaminate the surrounding well water. This study aims to determine the effect of leachate on the quality of well water around the Talang Gulo TPA settlement. Methods : This type of research is a quantitative cross sectional design. With a sample of 1 leachate and 49 well water. Determination of the sampling point is between 0-300 m, 301-600 m, and 601-900 m. Sampling by means of Grab Sampling. Data collection was carried out in situ and laboratory tests. The results obtained were compared with the quality standard requirements and analyzed using the Pollutant Index (IP) method. Results : The results showed that leachate from the Talang Gulo TPA had an effect on the COD and pH parameters on the quality of well water with an average IP quality status of = 1.31 in the lightly polluted category, while the distance from the TPA had an effect on the pH parameters on the quality of well water with an average IP quality status. averaged at a distance of 0-300 m, 301-600 m, and 601-900 m with an average value = 1.60, 1.26, and 1.20, all of which are still classified as light pollution. Conclusion : There is an influence of leachate on COD parameters and there is a pH of the effect of landfill distance on pH parameters on the quality of well water around the Talang Gulo TPA settlement in Jambi City. Keywords : TPA Garbage, Lindi, Well Water Quality, Pollutant Index
Type: | Thesis (S1) |
---|---|
Subjects: | L Education > L Education (General) |
Divisions: | Fakultas Kedokteran dan Ilmu Kesehatan > Ilmu Kesehatan Masyarakat |
Depositing User: | MONA CLARISHA |
Date Deposited: | 14 Jul 2021 03:31 |
Last Modified: | 14 Jul 2021 03:31 |
URI: | https://repository.unja.ac.id/id/eprint/22425 |
Actions (login required)
![]() |
View Item |