tarigan, Novita sari (2021) ANALISIS DOSIS PAPARAN RADIASI RUANGAN PESAWAT SINAR-X DI UNIT RADIOLOGI RSUD H. ABDUL MANAP JAMBI. S1 thesis, universitas jambi.
Text
Abstrak-dikonversi.pdf Download (72kB) |
|
Text
BAB I-dikonversi.pdf Download (126kB) |
|
Text
WhatsApp Image 2021-10-01 at 10.11.35-dikonversi.pdf Download (72kB) |
|
Text
DAFTAR PUSTAKA-dikonversi.pdf Download (98kB) |
|
Text
BAB V-dikonversi.pdf Download (69kB) |
|
Text
Skripsi Novita Sari Tarigan.pdf Download (2MB) |
|
Text
COVER.pdf Download (199kB) |
Abstract
[ANALISIS DOSIS PAPARAN RADIASI RUANGAN SINAR-X DI UNIT RADIOLOGI RSUD H. ABDUL MANAP JAMBI] The purpose of this study was to determine the dose of radiation exposure produced by x-ray aircraft at different voltage variations and distances in the radiology unit of H. Abdul Manap Hospital Jambi and then compare the suitability of the data obtained with the data on the provisions of BAPETEN regulations Number 4 Year 2013. Data collection activities were carried out at several measurement points, namely the front PB wall of the x-ray machine, the rear PB wall of the x-ray plane, the right PB wall of the x-ray plane, and the left PB wall of the x-ray plane. then at each point of the data collection position, distance and voltage variations are also used at each measurement point, namely the distance variation of 1m, 2m, and 3m then for the voltage variations used are 48 kV, 50 kV and 52 kV. Data retrieval is carried out in 10 repetitions then the data obtained is searched for the average value and standard deviation value. The value of the exposure dose resulting from variations in voltage, distance and different measurement points is with an average value of 0.08 mSv - 0.13 mSv and the standard deviation value obtained is 0.01 - 0.03 which can be said that the value of The data obtained are quite accurate. Based on the maximum value of the exposure dose per year according to BAPETEN regulations, which is a maximum of 1 mSv/year and when compared with the value of the data obtained, it can be concluded that the measured exposure dose value is still safe and the x-ray machine is suitable for use in the hospital.
Type: | Thesis (S1) |
---|---|
Subjects: | L Education > L Education (General) L Education > LB Theory and practice of education > LB1501 Primary Education |
Divisions: | Fakultas Sains dan Teknologi > Fisika |
Depositing User: | TARIGAN |
Date Deposited: | 04 Oct 2021 03:02 |
Last Modified: | 04 Oct 2021 03:02 |
URI: | https://repository.unja.ac.id/id/eprint/26939 |
Actions (login required)
View Item |