Analisis Kualitas Daya Listrik Di Gedung Gereja Utama HKBP Jambi

N, Gerardo (2024) Analisis Kualitas Daya Listrik Di Gedung Gereja Utama HKBP Jambi. S1 thesis, UNIVERSITAS UNJA.

[img] Text
FULL SKRIPSI.pdf
Restricted to Repository staff only

Download (6MB)
[img] Text
BAB I.pdf

Download (68kB)
[img] Text
BAB V.pdf

Download (87kB)
[img] Text
COVER.pdf

Download (1MB)
[img] Text
DAFTAR PUSTAKA.pdf

Download (115kB)
[img] Text
HALAMAN PENGESAHAN.pdf

Download (984kB)
Official URL: https://repository.unja.ac.id/

Abstract

Kualitas daya listrik merupakan hal penting bagi konsumen maupun pengelola, suplai energi listrik yang andal dan efisien serta berkualitas tinggi tentu diperlukan. Terputusnya aliran listrik secara tiba-tiba dan sering terjadi kerusakan pada alat-alat elektronik di Gedung Gereja HKBP Jambi membuat penulis melakukan penelitian tentang analisis kualitas daya di Gedung tersebut. Tujuan dari penelitian untuk menganalisis kualitas daya listrik di Gedung Gereja HKBP Jambi. Metode penelitian yang digunakan merupakan gabunngan metode kuantitatif dan kualitatif. Rendahnya kualitas daya listrik pada Gedung Gereja HKBP Jambi disebabkan nilai faktor daya pada fasa S di panel utama Gedung berkisar 0,75 – 0,83. Kemudian ketidakseimbangan beban pada panel utama berada pada kisaran 11,1% hingga 14,1%. Distorsi harmonik arus (THDi) yang tinggi, dengan nilai presentase antara 20,1 % hingga 27,8%, nilai tersebut merupakan angka yang tergolong tinggi. Hasil ini menunjukan perlunya perbaikan pada sistem kelistrikan untuk meningkatkan kualitas daya listrik di Gedung tersebut. The quality of electrical power is important for consumers and managers, efficient and high quality supply of electrical energy is certainly needed. Sudden power cuts and frequent damage to electronic equipment in the HKBP Jambi Church Building prompted the author to conduct research on the analysis of the quality of electrical power in the building. The aim of the research is to analyze the quality of electrical power in the HKBP Jambi Church Building. The research method used is a combination of quantitative and qualitative methods. The low quality of electrical power in the HKBP Jambi Church Building is due to the power factor value in the S phase in the main panel of the building ranging from 0.75 - 0.83. Then the load imbalance on the main panel is in the range of 11.1% to 14.1. High current harmonic distortion (THDi), with a percentage value between 20.1% to 27.8%, this value is a relatively high figure. These results indicate the need for improvements to the electrical system to improve the quality of electrical power in the building. Keywords : Power quality, harmonics, power factor, load imbalance.

Type: Thesis (S1)
Uncontrolled Keywords: Power quality, harmonics, power factor, load imbalance
Subjects: L Education > L Education (General)
Divisions: Fakultas Teknik > Teknik Elektro
Depositing User: N
Date Deposited: 23 Jan 2025 04:30
Last Modified: 23 Jan 2025 04:30
URI: https://repository.unja.ac.id/id/eprint/75218

Actions (login required)

View Item View Item